Condition fuel or flare gas:
OilPro's Liquid Stripper design drops, captures, and monetizes typical flare stack or tank vent "wet" gas liquids. The remaining conditioned gas is OEM spec fuel for on-site generation equipment or delivers a clean burning flare. Power use includes site needs, grid sales, or data operations. Valuable condensate is monetized and engines run optimally.
Condition injection gas:
The Micro Refrigeration Unit strips liquids and conditions injection gas for optimal results. Monetize condensate while improving injection gas. Results include better injection performance and fewer downhole equipment issues caused by condensates.
Feature overview:
- Minimal package footprint with compact, engineered components
- Simple, durable refrigeration system, serviceable by HVAC technicians
- Refrigerant is safer than propane, reduces on-site hazards
- Low temp. separator (LTS) for improved separation
- High quality, common brand component metallurgy and trim
Liquid Recovery Unit-30 HP-New
Designed for 900-1100 MSCF/d total flow.
Note:
This skid's flowrange variance is gas composition dependent and requiries verification by OilPro's process engineering team.
This system includes a 5 HP upstream dehydrator section for cases where initial dewatering is required or end-users would like to mitigate methanol use.
Summary:
-40 deg F capable system
Skid Mounted, c.w.:
Inlet coalescing vessel c.w.
Filter
Packaged with dual controls:
A. 5 HP Dehydration section c.w.
- 2 stainless steel heat exchangers
- Liquid dump valve for above
B. 20 HP section c.w.
- 2 stainless steel heat exchangers
- Liquid dump valve for above
H2S compatible materials
2" SCH 40 inlet and outlet piping for gas
1" SCH 40 Product outlet
Electrical:
Single Phase
480 Volt
Major Component Description:
AC-1000: Refrigerant Condenser
1/2" tubing c.w.
fins for optimized heat dispersion
V-1: Inlet Knockout/Coalescer combination vessel
Custom sized for application.
MAWP: 245 psig @ 250 deg F
MDMT: -40 deg F @ 245 psig
Coalescer, custom design
ASME Sec. VIII Div. 1 design
NB Registered, CRN for Canadian applications
C-100: Refrigeration Unit
Scroll compressor
MAWP: 415+ PSIG @ -40 deg F
Refrigerant 448A
20 HP/ ??A/ 60 Hz/ single phase
V-100: Receiver:
Sized for application
MAWP 450 PSIG
6' x 18"
E-1: Gas/Gas Exchanger
MAWP: 675 PSIG
design rate to match process conditions
316 SS construction
E2: Chiller
MAWP 675 PSIG
316 SS construction
E3: Pre-Cooler
Liquid to gas exchanger (Refrigerant)
MAWP 675 PSIG
tube and tube configuration
V2: Cold Separator
875 PSIG
~24" x 6' s/s
304 SS tubes, 0.125" walls
Customer to supply:
1. Two-phase separator
2. Cold Weather Enclosure
3. Methanol supply, pump and storage
- Methanol Injection Pump
- MAWP 1500 psig
- ~20 USGPM/d capacity
- 120VAC
4. Product storage tank
5. Outlet filter
-mounted to skid c.w. bypass, filter element.
Show Less